LS 04:07 PM redpesk OS Support #63 (Resolved): Access to a second CAN bus
Louis-Baptiste Sobolewski

03/18/2024

LS 04:29 PM redpesk OS Bug #101: modbus-binding serial - After an "action: read" times out, another "action: read" reads the answer to the previous query instead of the current one
Fix which flushes input buffer before sending a request after a time out: any possible late answer is discarded before sending a new request
Please note that the timeout value of this device should still be increased to avoid errors
Louis-Baptiste Sobolewski
LS 04:27 PM redpesk OS Bug #101 (Resolved): modbus-binding serial - After an "action: read" times out, another "action: read" reads the answer to the previous query instead of the current one
Louis-Baptiste Sobolewski

03/14/2024

LS 04:14 PM redpesk OS Bug #101 (In Progress): modbus-binding serial - After an "action: read" times out, another "action: read" reads the answer to the previous query instead of the current one
Louis-Baptiste Sobolewski
LS 04:12 PM redpesk OS Bug #101 (Resolved): modbus-binding serial - After an "action: read" times out, another "action: read" reads the answer to the previous query instead of the current one
Could be that the RTU answers properly but after the timeout, which means that the binding's next `read` reads the answer which was late and is waiting in the device's read buffer. Louis-Baptiste Sobolewski
LS 04:13 PM redpesk OS Feature #62: modbus-binding should support RTU Modbus in addition to TCP Modbus
Emmanuel Jubera [SAFT] wrote in #note-5:
> We use modbus-binding to get values from the ANDIVI RHT sensor.
> ...
See <https://bugs.redpesk.bzh/issues/101>
Louis-Baptiste Sobolewski

01/26/2024

LS 03:17 PM redpesk OS Feature #62 (Resolved): modbus-binding should support RTU Modbus in addition to TCP Modbus
Louis-Baptiste Sobolewski