General

Profile

Louis-Baptiste Sobolewski

  • Login: lbsobolewski
  • Registered on: 11/21/2023
  • Last sign in: 11/21/2023

Issues

open closed Total
Assigned issues 1 3 4
Reported issues 0 1 1

Projects

Project Roles Registered on
redpesk Factory Developer, Reporter 11/21/2023
redpesk OS Developer, Reporter 11/21/2023

Activity

06/13/2024

04:07 PM redpesk OS Support #63 (Resolved): Access to a second CAN bus
Louis-Baptiste Sobolewski

03/18/2024

04:29 PM redpesk OS Bug #101: modbus-binding serial - After an "action: read" times out, another "action: read" reads the answer to the previous query instead of the current one
Fix which flushes input buffer before sending a request after a time out: any possible late answer is discarded befor... Louis-Baptiste Sobolewski
04:27 PM redpesk OS Bug #101 (Resolved): modbus-binding serial - After an "action: read" times out, another "action: read" reads the answer to the previous query instead of the current one
Louis-Baptiste Sobolewski

03/14/2024

04:14 PM redpesk OS Bug #101 (In Progress): modbus-binding serial - After an "action: read" times out, another "action: read" reads the answer to the previous query instead of the current one
Louis-Baptiste Sobolewski
04:12 PM redpesk OS Bug #101 (Resolved): modbus-binding serial - After an "action: read" times out, another "action: read" reads the answer to the previous query instead of the current one
Could be that the RTU answers properly but after the timeout, which means that the binding's next `read` reads the an... Louis-Baptiste Sobolewski
04:13 PM redpesk OS Feature #62: modbus-binding should support RTU Modbus in addition to TCP Modbus
Emmanuel Jubera [SAFT] wrote in #note-5:
> We use modbus-binding to get values from the ANDIVI RHT sensor.
> When i...
Louis-Baptiste Sobolewski

01/26/2024

03:17 PM redpesk OS Feature #62 (Resolved): modbus-binding should support RTU Modbus in addition to TCP Modbus
Louis-Baptiste Sobolewski

Also available in: Atom